local device = {} device.model = "SA12IZL" device.vendor = "Tuya" device.description = "Smart smoke alarm" device.fingerprint = { { model = "TS0601", manufacturer = "_TZE200_5d3vhjro", }, } device.exposes = { { type = "numeric", name = "battery", property = "battery", access = 1, unit = "%", min = 0, max = 100, description = "Remaining battery in %, can take up to 24 hours before reported", category = "diagnostic", }, { type = "binary", name = "smoke", property = "smoke", access = 1, value_on = true, value_off = false, description = "Smoke alarm status", }, { type = "enum", name = "battery_level", property = "battery_level", access = 1, description = "Battery level state", values = { "low", "middle", "high" }, }, { type = "binary", name = "alarm", property = "alarm", access = 3, value_on = true, value_off = false, description = "Enable the alarm", }, { type = "binary", name = "silence_siren", property = "silence_siren", access = 3, value_on = true, value_off = false, description = "Silence the siren", }, } device.tuya = { magicPacket = true, } device.fromZigbee = { "battery" } device.tuyaDatapoints = { { dp = 1, name = "smoke", converter = "trueFalse0" }, { dp = 15, name = "battery", converter = "raw" }, { dp = 16, name = "silence_siren", converter = "trueFalse1" }, { dp = 20, name = "alarm", converter = "trueFalse0" }, } device.configure = { bind = { "genPowerCfg" }, reporting = { { cluster = "genPowerCfg", attribute = "batteryPercentageRemaining", min = 3600, max = 65000, change = 0, }, { cluster = "genPowerCfg", attribute = "batteryVoltage", min = 3600, max = 65000, change = 0, }, }, } return device